Home > 14 > 12

Title: 14 - Buildings and Constructions

Chapter: 12 - On-Site Sewage Disposal Systems

Section: 130 - Appendix

Table A, minimum setback distances, and Table B, quantities of sewage flows, are set out as follows:

                                                                     TABLE A

 

MINIMUM SETBACK DISTANCES

 

                              Sewage Disposal Area                      Septic Tank and

Item Requiring               (including replacement                     Other Treatment

   Setback                       area, in feet)                         Units (in feet)

 

Property lines                      10                                        10

 

Water line                          10                                        10

 

Foundation lines of

building, including

outbuildings                        10                                        5

 

Wells                               100                                       100

 

Perennial flowing

      stream *1                     100                                       100

 

Ephemeral stream *22                50                                        50

 

Ocean, lake, reservoir *3           100                                       50

 

Cut bank, bluffs and

sharp changes in slope              25 *4                                     25

 

*1 As measured from the line which defines the limit of the ten-year flood.

*2 As measured from the edge of the watercourse.

*3 As measured from the high water line.

*4 Where soil depth or depth to groundwater below the leach­ing trench are less than five feet, a minimum setback distance of fifty feet shall be required.

                                                TABLE B

 

  QUANTITIES OF SEWAGE FLOWS

 

                                         Minimum Gallons

                                   Gallons Per Per Establishment

Type of Establishment                          Day                                 Per Day

Airport                                   5 (per passenger)                         150

 

Bathhouses and swimming pools             10 (per person)                           300

 

Camps: (4 persons per camp site,

where applicable)

Campground with central comfort stations  35 (per person)                           700

 

With flush toilets, no showers            25 (per person)                           500

 

Construction camps (semi-permanent)       50 (per person)                           1,000

 

Day camps (no meals served)               15 (per person)                           300

 

Resort camps (night and day)

with limited plumbing                     50 (Per person)                           1000

 

Luxury camps                              100 (per person)                          2000

 

Churches                                  5 (per seat)                              150

 

Country clubs                             100 (per resident member)                 2000

 

Country clubs                             25 (per nonresident member)               --­-

 

Dwellings:

Boarding houses                           150 (per bedroom)                         600

  Additional for non­-resident borders     10 (per person)                           ---

 Rooming houses                          80 (per person)                           500

 Condominium, multiple ­family dwellings

(includ­ing apartments)                   150 (per bedroom)                         900

 

Single-family dwellings                   300 (not exceeding 2 bedrooms)            450                   

 

 with more

 than 2 bedrooms                          75 (for third and each succeeding bedroom)450              

 

Factories

(exclusive of industrial wastes)          35 (per person per shift)                 300

 with shower facilities                              

 

Factories

(exclusive of industrial wastes)          15 (per person per shift)                 150

 without shower facilities

 

Hospitals                                 250 (per bed space)                       2500

 

Hotels with private baths                 120 (per room)                            600

 

Hotels without private baths              100 (per room)                            500

 

Institutions other than hospitals         125 (per bed space)                       1250

 

Laundries, self-service                   500 (per machine)                         2500

 

Mobile home parks                         250 (per space)                           750

 

Motels (with bath, toilet,

and kitchen wastes)                       200 (per bedroom)                         500                    

 

Motels (without kitchen)                  80 (per bedroom)                          400  

 

Picnic parks (toilet wastes only)         5 (per picnicker)                         150

 

Picnic parks (with bath­houses,

showers and flush toilets)                10 (per picnicker)                        300

 

Restaurants                               40 (per seat)                             800

 

Restaurants (single-service)              2 (per customer)                          300

 

Restaurants (with bars and/or lounges)    50 (per seat)                             1000                        

 

Schools:

Boarding                                 100 (per person)                          3000

Day without gyms, cafeterias, and showers15 (per person)                           450

Day, with gyms, cafe­

 terias and showers                       1-5 (per person)                          750

 Day, with cafeteria, but

 without gyms or showers                  20 (per person)                           600

 

Service stations                          10 (per vehicle serviced)                 500

 

Swimming pools and bathhouses             10 (per person)                           300

 

Theaters:

      Movie                               5 (per seat)                              300

      Drive-in                            20 (per car space)                        1000

 

Travel trailer parks (without

 individual water and sewer hookups)      50 (per space)                            300

Travel trailer parks (with

 individual water and sewer hookups)      100 (per space)                           500

 

Workers:

 Construction (as semi­-permanent camps)   50 (per person)                           1000

 

Day, at schools and offices               15 (per shift)                            150

 

 

(Ord. 88-34 § 2 (part), 1988.)